| HOME>POWER SUPPLIES MENU> >MIL-STD-704A | Please click here for your inquiry for this product. |
| English version | |
| For MIL-STD-704A, |
||
| POWER SUPPLY CHANGE TEST SYSTEM |
||
![]() |
![]() |
|
| This system allows you to obtain conveniently programmed power supply outputs
which you may use to evaluate performance of airborne eqquipment against
power supply changes meeting the requirements of MIL-STD-704A. With the built-in system computer, you can readily program the standard airborne equipment power supplies [115 V, 400 Hz, 3-phase AC; 28 V DC] for test with changes in starting time difference between AC and DC,and in duration, amplitude, and other parameters. |
||
| Typical test output waveforms |
|||
| 3-phase output change waveform |
Test of DC change after starting AC change | ||
![]() |
![]() |
||
| Start of AC change after starting DC change | Setting the starting gradient | ||
![]() |
![]() |
||
| Rated AC Output: | 115 V (phase voltage), 400 Hz, 4-wire 3-phase | ||
| Rated DC Output: | +28 V | ||
| Variable Voltage Range: | 0 to 300 V AC, 0.1-V steps | ||
| Change Start Phase Angle: | 0 to 359.9 deg., 0.1-deg steps |
||
| Change Duration: | 0.1 msec to 65000 msec | ||
| Starting Gradient: | 0 to 65000 msec. 1-msec steps | ||
| Restoring Gradient: | 0 to 65000 msec. 1-msec steps | ||
| AC/DC Change Start Time Difference | +/-1000 msec, 1-msec steps | ||
| Number of Repetitions: | 1 to 255 |
|
||
![]() |
![]() |
Please click here for your inquiry for this product. |